AccueilCasIngénierie environnementale : couvertures à membrane – Étude de cas sur des réservoirs et des bassins

Ingénierie environnementale : couvertures à membrane – Étude de cas sur des réservoirs et des bassins

2026-10-19

Partager :

A tank cover is an environmental barrier first and a roof second. It contains odour, reduces evaporation, limits algae and keeps debris out, while letting gas out and people in.

These reference views show a peaked cover over a treatment tank, a circular tank cover and a large basin array.

Couvercle à membrane bombée recouvrant un bassin de traitement des eaux usées
A single peaked cover seals a treatment tank while leaving the perimeter accessible

Aperçu du projet

Élément Champ d'application de référence
Application Wastewater, aeration, sludge and reservoir tanks
Typical tank size 6–60 m diameter
Formulaires Peaked cover, circular cover, low-profile basin cover
Membrane et cadre PVC/PVDF or HDPE; coated steel or stainless
Facteurs déterminants de la conception Odour, gas venting, access, corrosion

Les défis que la conception doit relever

  • Contain gas, but let it out. Provide controlled extraction and pressure relief.
  • Select for the atmosphere. Hydrogen sulphide and humidity attack steel and aluminium.
  • Design access. Hatches, walkways and lifting points are part of the cover.
  • Check perimeter uplift. Large lightweight covers are sensitive to wind and snow drift.

Formes de toiture dans cet ensemble de référence

Circular tank cover

A circular cover follows the tank wall and can be divided into segments for maintenance. The membrane is tensioned to a perimeter ring and a central support.

Circular membrane cover over a large treatment tank
A circular cover follows the tank geometry and can be segmented for maintenance

Basin array

Repeated low-profile covers control odour across a large treatment site. Repetition reduces cost and allows the covers to be installed in phases.

Rows of membrane covers over water treatment basins
Repeating covers over a basin array control odour and algae across a large site

Matériaux et livraison

PVC/PVDF and HDPE are common cover materials. The choice depends on the gas composition, temperature and expected service life.

  • PVC/PVDF 900–1100 g/m² or HDPE 1.0–2.0 mm
  • Galvanised steel; stainless or FRP for high H2S exposure
  • Stainless A4 fixings and isolation washers

Foire aux questions

What is the main purpose of a tank cover?

To contain odour and gas, reduce evaporation, limit algae growth and keep debris out of the water. It also improves safety by controlling access.

Can the cover be walked on?

Only where a designated walkway with fall protection has been designed. The membrane itself is not a walking surface.

How is gas extracted?

Through a dedicated extraction point at the high point, connected to an odour-control system. Pressure relief is designed with the process engineer.

Discutez d'un projet similaire

Send the tank dimensions, process conditions and access requirements. We will review the cover form and materials.

À lire également : Sustainable membrane structure design

Envoyez-nous votre cahier des charges · Gamme de produits à structure membranaire

Article recommandé

Demander un devis

Prêt à discuter de votre projet de structure à membrane ?

Partagez avec notre équipe le périmètre, les dimensions, le scénario d’utilisation et le lieu de votre projet ; nous vous aiderons à examiner les options structurelles, le choix des matériaux et les éléments de chiffrage pour définir la prochaine étape.

Envoyer une demande Demander un devis
N'hésitez pas à nous contacter