الرئيسيةحالاتمظلات للممرات والقنوات: دراسة حالة «Covered Link»

مظلات للممرات والقنوات: دراسة حالة «Covered Link»

2026-10-19

مشاركة:

A covered walkway is judged by the dry route it provides, not the roof seen from above. Continuity, drainage and the junctions with buildings decide whether it works.

These reference views show a long barrel vault, a cantilevered facade canopy and a funnel-column entrance.

مظلة غشائية طويلة ذات قبة أسطوانية فوق ممر خاص بالشركة
A continuous barrel-vault canopy gives a clean, weather-protected route between buildings

لمحة عامة عن المشروع

البند نطاق المرجع
مجال الاستخدام Station, campus, hospital, public promenade
Clear width 2.5–6 m, wider at entrances
النماذج Barrel vault, cantilever, lattice, funnel column
الغشاء والإطار PVC/PVDF على الفولاذ المجلفن
عوامل التصميم Continuous cover, drainage, movement, lighting

ما الذي يتعين على التصميم معالجته

  • Keep the covered width usable. Columns, drainage and lighting all take space from the walking route.
  • Avoid gaps. Joints between canopy modules and buildings create wet spots where people slow down.
  • Collect water above head height. Discharge it away from the walking surface.
  • Allow for movement. Long walkways need movement joints and sliding connections rather than rigid restraint at both ends.

قوالب الأسقف في هذه المجموعة المرجعية

Cantilever along a facade

A single-sided canopy leaves the walkway open. The facade must take the uplift, and the anchor detail must keep the building weathertight.

Cantilevered walkway canopy along a building facade
A single-sided canopy keeps the walkway open while sheltering the route along the facade

Funnel-column entrance

A funnel column carries the roof and collects rainwater in one element. Access for cleaning the internal pipe is essential.

Funnel-shaped membrane columns at a station entrance
Funnel columns combine structure and rainwater collection in one element

المواد والتسليم

Walkways are high-traffic structures, so the membrane should stay clean and the underside should be easy to inspect.

  • PVC/PVDF 850–1100 g/m² in white or a light colour
  • فولاذ مجلفن مطلي بطلاء مسحوق في الأجزاء الظاهرة
  • Aluminium gutters with leaf guards and accessible outlets

الأسئلة الشائعة

How wide should a covered walkway be?

As a guide, 2.5–3 m suits a campus link. Station walkways are usually wider and are set by the transport authority's design standards.

Can it connect to an existing facade?

Yes, with a designed flashing and movement joint. The facade structure must be checked for the canopy loads.

Can it be installed while the building stays open?

Usually yes. The work is phased, with temporary protection for the walking route.

ناقش مشروعًا مشابهًا

Send the route plan, building interfaces and required clear width. We will review the canopy form, drainage and connection details.

مقالات ذات صلة: حلول مخصصة للمظلات الغشائية

أرسل موجز مشروعك · مجموعة منتجات الهياكل الغشائية

منشور موصى به

احصل على عرض أسعار

هل أنتم مستعدون لمناقشة مشروع هيكل الغشاء الخاص بكم؟

شارك فريقنا نطاق مشروعك وأبعاده وسيناريو استخدامه وموقعه، وسنساعدك في مراجعة الخيارات الإنشائية واتجاه اختيار المواد وتفاصيل عرض السعر للخطوة العملية التالية.

إرسال استفسار طلب عرض سعر
لا تتردد في الاتصال بنا